클링커 냉각속도의 정량적 해석 및 냉각속도가 시멘트 강도발현에 미치는 영향고찰 |
김창범, 최성철1 |
쌍용기술연구소 1한양대학교 신소재공학부 |
Quantitative Interpretation of Cooling Rate of Clinker and It's Effects on the Cement Strength Development |
Chang-Bum Kim, Sung-Churl Choi1 |
Research Center of Ssangyong Cement Industrial Co., Ltd 1Department of Materials Science and Engineering, Hanyang University |
|
|
|
ABSTRACT |
To evaluate the cooling rate of clinker quantitatively, several clinkers with different cooling rate were made in the laboratory. The X-ray diffraction pattern of Ferrite 002 reflection were measured and the parameters were calculated by using split type pseudo-Voigt function. The X-ray diffraction patterns of the Ferrite phase in the clinkers from cement manufacturing plant were analyzed by using the parameters and the analysis program was developed to calculate the cooling rate quantitatively. The cooling rate coefficients of the clinkers were calculated by using the profile fitting method of the program and the influence of cooling rate on strength was evaluated. The results show that there is a close relation between the cooling rate of clinker and the strength of cement. |
Key words:
Ferrite phase, X-ray diffraction pattern, Profile fitting, Cooling rate coefficient, Clinker particle size, Compressive strength |
|
|
|